Installing and launching¶
Requirements¶
| Operating system | Windows 10 or 11, 64-bit |
| Graphics | Any GPU or software renderer; PlatAnJr draws through Skia |
| Memory | Depends entirely on your data - see Memory and event counts |
| Disk | The application plus a small settings folder; PlatAnJr writes analysis metadata next to your data |
PlatAnJr is a single executable, PlatAnJr.exe. There is no separate runtime to install.
Launching¶
Start PlatAnJr.exe normally, or pass it a plate folder - and optionally a project - on
the command line:
PlatAnJr.exe "D:\Experiments\Plate 17"
PlatAnJr.exe "D:\Experiments\Plate 17" "D:\Experiments\Plate 17\INFO\screen.ppj"
With one argument PlatAnJr opens the folder as a plate without showing the Plate dialog, reusing the well layout already stored in that folder. With two, it then loads the project file on top of it.
You can also drag a folder from Explorer and drop it on the plate image in the Heat Map tab.
Where settings are kept¶
PlatAnJr keeps its own preferences in a per-user folder:
%APPDATA%\PlatAnJr\
This holds PlatAnJr.ini (window and option settings, recently used folders, the last
project backup) and a few support folders. Nothing in it is needed to read your data - it
is safe to delete if you want to reset the application to defaults.
Everything that belongs to a particular dataset - the plate layout, saved projects,
parameter defaults, unmixing panels - lives in an INFO folder inside the data folder
instead. See Files and folders.
Shared data and updates¶
The installer also puts data shared by every dataset in C:\Users\Public\Documents -
this manual, the CD database and the spectra used by unmixing;
see Files and folders.
The spectrum collection and the device functions are
yours to add to, in PlatAnJr and in BFSpectra alike, so an update keeps them and adds only
what you lack. When there is
something of yours it could replace, Setup shows an Existing data page offering to
replace the collection, the device functions, or both, with the installer's; a replaced
collection is kept as SpectrumDB.DB.bak. The ones PlatAnJr 2.34 and BFSpectra 2.24
installed had errors, and are replaced without asking.
The CD database is replaced on every install: keep a copy of one you have edited.
Memory and event counts¶
A plate is loaded into memory in full: every event of every well, for every parameter you selected. A 96-well plate with 200 000 events per well and 30 parameters is roughly 2.3 GB of floating-point data before any derived parameter is added.
Two controls keep this manageable while you are still setting up an analysis:
- Preview mode (the toolbar button that is pressed by default) loads only a fraction of each file.
- Select Parameters in the Plate dialog loads only the channels you name.
Both are described in Opening a plate. Turn preview off and reload when you are ready to produce final numbers.
Checking for updates¶
The toolbar has a Check for updates button. It contacts the update service, reports whether a newer build exists, and offers to fetch it.