Skip to content

Looking at colonies

The active plate is the one selected in the tree; the active colony is the one its plate image, table and scatter image are showing.

Choosing a colony

Any of these makes a colony active, and the others follow:

  • click on the plate image: the nearest colony is chosen;
  • click a thumbnail in the bottom band;
  • click a row of the table;
  • move the scroll bar left of the tabs;
  • click a point on the PCA for SVM or PCA tSNE UMAP etc chart.

The plate image

Every ticked colony with a position has a circle of its measured diameter. The colour is its class, red before it has one. The active colony has a yellow tag with its number.

Show Colony Numbers on the top toolbar labels all of them. The legend in the corner counts the colonies of each class, with their percentages.

If the circles do not sit on the colonies, the plate's scale is wrong: see Dots per millimetre.

The table

One row per colony of the active plate:

Column Meaning
Number The colony's number on the plate
Class The class given by the classifier or by clustering, N/A before that
Prob The probability of that class, from 0 to 1
X, Y The position on the plate, in mm from its centre
Diameter The colony's diameter, in mm
Roundness How round it is, as measured by BacBuster
Center X, Center Y The centre of the scatter image, in pixels
Exposure(mS) The camera's exposure
HDRmin(mS), HDRmax(mS), HDRdecades The range of exposures of a high-dynamic-range image
Zoom The camera's zoom
Mygoodness A quality score for the image, when BacBuster has given it one

Click a column's heading to sort by it, from Number to Center Y; click again to reverse the order. The thumbnails follow the same order.

The thumbnails

A colony with its box unticked is left out of everything: training, classification, clustering, the circles on the plate image and the counts. Right-click the band for Select All and DeselctAll.

The scatter image

The Colony tab shows the image at full size, with a cross on its centre. To move the centre, point at a line of the cross, where the cursor changes, and drag it; drag where the lines meet to move both. On the Training Set this marks the model as changed.

Colorify Scatter on the Options tab shows the image in false colours.

With no colony active the tab shows a green AVAILABLE stamp. That is not an error: choose a colony.

The Pseudo tab shows the image after the filters, with the features of the colony as a small picture in its corner. Change a filter and it follows.

The Histogram tab

Four views of the active colony:

View Shows
Intensity How many pixels have each grey level
Average Radius The average distance from the centre of the pixels at each grey level
Radial Distribution The intensity against the distance from the centre
One-Hot Vector The class scores given by a neural net. It stays empty in this version

The Info tab

The active plate's details: Plate Name, Experiment, Date Time, Incubation, Device ID, Doer, Lab, Media, Source and DPM. Change them with Save Plate.